Product Description

Recently,with rapid development fo PCB industry,more and more manufacturers begin to research and develop and  produce PCB digital control milling and drilling machines.At present,rolling-ball type and air suspending type,with one to eight spindles,are widely used.A perfect and precise cooling system will prolong the service life and effectively control the precision of the spindles.

 Model
Item
 
APL-03
 
APL-05
 
APL-06
 
APL-08(D)
 
nominal cooling capacity
 
kcal/h
 
6803
 
11094
 
13091
 
17604
 
kw
 
7.91
 
12.9
 
15.23
 
20.47
 
input power
 
kw
 
3.33
 
5.8
 
6.33
 
9.25
 
power supply
 
3~380V 50HZ
 
refrigerant
 
type
 
R22
 
type of control
 
capillary
 
thermostatic expansion valve
 
compressor
 
type
 
hermetic scroll
 
power(kw)
 
2.8
 
4.66
 
5.2
 
3.8×2
 
condenser
 
type
 
finned copper tube + low noise outer rotor fan
 
cooling air flow
(m 3 /h)
 
3000
 
5000
 
6000
 
8000
 
evaporator
 
type
 
tank with coil
 
chilled fluid flow(m 3 /h)
 
1.36
 
2.22
 
2.6
 
3.52
 
volume(L)
 
50
 
70
 
70
 
120
 
inlet and outlet pipe diameter (inch)
 
1
 
1
 
1
 
1
 
pump
 
power(kw)
 
0.37
 
0.75
 
0.75
 
0.75
 
lift(m)
 
20
 
20
 
20
 
22
 
safety protection
 
compressor over temperature, over current, high and low pressure, over temperature,flow Switch, phase sequence, phase-missing, exhaust overheating, antifreezing
 
weight
 
mm
 
135
 
175
 
180
 
310
 
dimension
 
mm
 
930*520*975
 
1140*560*1040
 
1140*560*1040
 
1310*720*1270
 
Note: 1. nominal cooling capacity is according to:
             Inlet chilled fluid temperature: 12
             Outlet chilled fluid temperature: 7
             Inlet cooling air temperature: 30
             Outlet cooling air temperature: 40
     2. working range:
             The temperature range of chilled fluid is from 5 to 35;
             Temperature difference between inlet and outlet chilled fluid is from 3 to 8.
             It is better to use the chiller while the ambient temperature at or below 35.
We reserve the right to modify the above dimensions or parameters without further notice.
 
         
Trademark: ANGES
Productivity: 300 sets/month
Unit Price/Payment: FOB Shenzhen
Company: Shenzhen Anges Machinery Co., Ltd.

Click here to send inquiry